东芝电梯的插子线的配置

东芝电梯的插子线的配置

CN5(D1):

A1<–XDC<–PC1A(110V)

B1–DCR

A2–A4

B2–A11

A3–XCC

B3–BLS1

A4–BLS2

B4–A10

A5–NC

B5–

A6–>DNLS–>NC2

B6–UPLS

A7–5LS

B7–6LS

A8–PAK

B8–FIM

A9–7LS

B9–8LS

 

CN5(D0)

A11<–OP(开门继电器线圈)<–P24A

B11–CL

A12–MC <–(MCRY1-3)<–(MCRY1-4)<–P24A[A12NC,MCRY112,MC线圈吸合.R3(8F-1)–>MC–>MCRY1-1–>MCRY1-2–>T3(8F-2)]

B12–MS1 <–(MCRY2-3)<–(MCRY2-4)<–P24A[A12NC,MCRY212,MC线圈吸合.R3(8F-1)–>MC–>MCRY2-1–>MCRY2-2–>T3(8F-2)]

A13–XMC

B13–SMR

A14–LBK

B14–XLBK1

A15–P24A

B15–NC2CNK1(20P)CAGE轿厢    CNH1(20P)HALL井道     CNM1(6P)M/R控制柜

1–LSA               1–DNLS               1–A10

2–LSB           2–UPLS               2–A10C

3–LSC               3–5LS                3–A10C

4–KNOR              4–6LS                4–A11

5–PLU               5–7LS

6–PLD               6–8LS

7–DLS               7

8–18DS              8–PC1A

9                    9–A2

10–K1               10–A7

11–K10              11–A10

12–A2               12–(A10)

13–A7               13–(A10A)

14–HDC              14–A11A

15–DC               15–HDC

16                   16–NC2H

17–COMD             17–PAK

18–OP               18–K3

19–CL               19–K10

20–A4               20–FIM

 

 

CNK2(6P)CAGE         CNH2(6P)HALL

1–P24C              1–P24H     

2–NC2C              2–P24H     

3–1WLS(105%)        3–P24H              

4–3WLS(80%)         4–NC2H             

5–8WLS(150kg)       5–NC2H           

6–EXPS              6–NC2H

 

 

CONTACT US

联系我们

微信公众号
24小时服务热线
4009-030-398
地址:深圳市龙华区民治街道北站社区鸿荣源北站中心B座2707-2709