东芝电梯的插子线的配置
东芝电梯的插子线的配置
CN5(D1):
A1<–XDC<–PC1A(110V)
B1–DCR
A2–A4
B2–A11
A3–XCC
B3–BLS1
A4–BLS2
B4–A10
A5–NC
B5–
A6–>DNLS–>NC2
B6–UPLS
A7–5LS
B7–6LS
A8–PAK
B8–FIM
A9–7LS
B9–8LS
CN5(D0)
A11<–OP(开门继电器线圈)<–P24A
B11–CL
A12–MC <–(MCRY1-3)<–(MCRY1-4)<–P24A[A12脚NC时,MCRY1的1和2通,MC线圈吸合.R3(8F-1)–>MC–>MCRY1-1–>MCRY1-2–>T3(8F-2)]
B12–MS1 <–(MCRY2-3)<–(MCRY2-4)<–P24A[A12脚NC时,MCRY2的1和2通,MC线圈吸合.R3(8F-1)–>MC–>MCRY2-1–>MCRY2-2–>T3(8F-2)]
A13–XMC
B13–SMR
A14–LBK
B14–XLBK1
A15–P24A
B15–NC2CNK1(20P)CAGE轿厢 CNH1(20P)HALL井道 CNM1(6P)M/R控制柜
1–LSA 1–DNLS 1–A10
2–LSB 2–UPLS 2–A10C
3–LSC 3–5LS 3–A10C
4–KNOR 4–6LS 4–A11
5–PLU 5–7LS
6–PLD 6–8LS
7–DLS 7
8–18DS 8–PC1A
9 9–A2
10–K1 10–A7
11–K10 11–A10
12–A2 12–(A10)
13–A7 13–(A10A)
14–HDC 14–A11A
15–DC 15–HDC
16 16–NC2H
17–COMD 17–PAK
18–OP 18–K3
19–CL 19–K10
20–A4 20–FIM
CNK2(6P)CAGE CNH2(6P)HALL
1–P24C 1–P24H
2–NC2C 2–P24H
3–1WLS(105%) 3–P24H
4–3WLS(80%) 4–NC2H
5–8WLS(150kg) 5–NC2H
6–EXPS 6–NC2H